Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 207
Filtrar
1.
Blood ; 2024 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-38657242

RESUMEN

In this retrospective study, CAR T-cells remained effective in relapsed/refractory LBCL patients after prior exposure to bispecific antibodies (BsAbs) targeting different antigens. These results are relevant to clinical practice, particularly given the increasing use of BsAbs in earlier treatment lines.

2.
Cancer ; 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38581695

RESUMEN

INTRODUCTION: For the majority of patients with acute myeloid leukemia (AML) an allogeneic stem cell transplant (SCT) in first complete remission (CR) is preferred. However, whether the number of courses required to achieve CR has a prognostic impact is unclear. It is unknown which factors remain important in patients requiring more than one course of induction to attain remission. METHODS: This Acute Leukaemia Working Party study from the European Society for Blood and Marrow Transplantation identified adults who received an allograft in first CR from either a fully matched sibling or 10/10 or 9/10 human leucocyte antigen (HLA)-matched unrelated donor (HLA-A, HLA-B, HLA-C, HLA-DR, or HLA-DQ). Univariate and multivariate analyses were undertaken to identify the prognostic impact of one or two courses of induction to attain CR. RESULTS: A total of 4995 patients were included with 3839 (77%) patients attaining a CR following one course of induction chemotherapy (IND1), and 1116 patients requiring two courses (IND2) to attain CR. IND2 as compared to IND1 was a poor prognostic factor in a univariate analysis and remained so in a multivariate Cox model, resulting in an increased hazard ratio of relapse (1.38; 95% confidence interval [CI], 1.16-1.64; p = .0003) and of death (1.27; 95% CI, 1.09-1.47; p = .002). Adverse prognostic factors in a multivariate analysis of the outcomes of patients requiring IND2 included age, FLT3-ITD, adverse cytogenetics, and performance status. Pretransplant measurable residual disease retained a prognostic impact regardless of IND1 or IND2. CONCLUSION: Initial response to chemotherapy as determined by number of courses to attain CR, retained prognostic relevance even following SCT in CR.

3.
Molecules ; 29(5)2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38474628

RESUMEN

The analysis of heroin samples, before use in the protected environment of user centra, could be a supplementary service in the context of harm reduction. Infrared spectroscopy hyphenated with multivariate calibration could be a valuable asset in this context, and therefore 125 heroin samples were collected directly from users and analysed with classical chromatographic techniques. Further, Mid-Infrared spectra were collected for all samples, to be used in Partial Least Squares (PLS) modelling, in order to obtain qualitative and quantitative models based on real live samples. The approach showed that it was possible to identify and quantify heroin in the samples based on the collected spectral data and PLS modelling. These models were able to identify heroin correctly for 96% of the samples of the external test set with precision, specificity and sensitivity values of 100.0, 75.0 and 95.5%, respectively. For regression, a root mean squared error of prediction (RMSEP) of 0.04 was obtained, pointing at good predictive properties. Furthermore, during mass spectrometric screening, 10 different adulterants and impurities were encountered. Using the spectral data to model the presence of each of these resulted in performant models for seven of them. All models showed promising correct-classification rates (between 92 and 96%) and good values for sensitivity, specificity and precision. For codeine and morphine, the models were not satisfactory, probably due to the low concentration of these impurities as a consequence of acetylation. For methacetin, the approach failed.


Asunto(s)
Heroína , Heroína/análisis , Calibración , Espectrofotometría Infrarroja , Análisis de los Mínimos Cuadrados
5.
Contact Dermatitis ; 90(6): 594-606, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38471795

RESUMEN

INTRODUCTION: Medical devices (MDs) have a long history of use, and come with regulatory frameworks to ensure user safety. Although topically applied MDs in the form of gels and creams might be used on damaged skin, their composition is often similar to that of cosmetic products applicable to intact skin, especially in terms of preservatives and fragrances. However, unlike cosmetics, these products are not subject to compound-specific restrictions when used in MDs. OBJECTIVE: This study aimed to identify and quantify preservatives and fragrances in topically applied MDs and assess their safety towards the Cosmetic Regulation (EC) 1223/2009. METHOD: Sixty-nine MDs available on the EU market were subjected to previously validated liquid chromatography tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) methods to identify and quantify occurring preservatives and fragrances. RESULTS: Findings revealed that 32% of the examined MDs did not provide comprehensive ingredient lists, leaving users uninformed about potential risks associated with product use. Furthermore, 30% of these MDs would not meet safety standards for cosmetic products and, most significantly, 13% of the analysed samples contained ingredients that are prohibited in leave-on cosmetics. CONCLUSION: Results highlight the pressing demand for more stringent requirements regarding the labelling and composition of MDs to enhance patient safety. Improved regulation and transparency can mitigate potential risks associated with the use of topically applied MDs.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Conservadores Farmacéuticos , Conservadores Farmacéuticos/análisis , Conservadores Farmacéuticos/efectos adversos , Humanos , Perfumes/efectos adversos , Perfumes/análisis , Cosméticos/análisis , Cosméticos/efectos adversos , Equipos y Suministros/efectos adversos , Unión Europea , Espectrometría de Masas en Tándem , Cromatografía Liquida , Seguridad de Productos para el Consumidor/legislación & jurisprudencia , Administración Tópica
6.
Clin Lymphoma Myeloma Leuk ; 24(4): e130-e137, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38267355

RESUMEN

Blastic plasmacytoid dendritic cell neoplasm (BPDCN) is an aggressive myeloid malignancy of the dendritic cell lineage that affects patients of all ages, though the incidence appears to be highest in patients over the age of 60 years. Diagnosis is based on the presence of plasmacytoid dendritic cell precursors expressing CD123, the interleukin-3 (IL-3) receptor alpha, and a distinct histologic appearance. Timely diagnosis remains a challenge, due to lack of disease awareness and overlapping biologic and clinical features with other hematologic malignancies. Prognosis is poor with a median overall survival of 8 to 14 months, irrespective of disease presentation pattern. Historically, the principal treatment was remission induction therapy followed by a stem cell transplant (SCT) in eligible patients. However, bridging to SCT is often not achieved with induction chemotherapy regimens. The discovery that CD123 is universally expressed in BPDCN and is considered to have a pathogenetic role in its development paved the way for the successful introduction of tagraxofusp, a recombinant human IL-3 fused to a truncated diphtheria toxin payload, as an initial treatment for BPDCN. Tagraxofusp was approved in 2018 by the United States Food and Drug Administration for the treatment of patients aged 2 years and older with newly diagnosed and relapsed/refractory BPDCN, and by the European Medicines Agency in 2021 for first-line treatment of adults. The advent of tagraxofusp has opened a new era of precision oncology in the treatment of BPDCN. Herein, we present an overview of BPDCN biology, its diagnosis, and treatment options, illustrated by clinical cases.


Asunto(s)
Neoplasias Hematológicas , Trastornos Mieloproliferativos , Neoplasias Cutáneas , Adulto , Humanos , Persona de Mediana Edad , Subunidad alfa del Receptor de Interleucina-3 , Interleucina-3/uso terapéutico , Neoplasias Hematológicas/diagnóstico , Neoplasias Hematológicas/tratamiento farmacológico , Medicina de Precisión , Enfermedad Aguda , Trastornos Mieloproliferativos/patología , Neoplasias Cutáneas/patología , Células Dendríticas/patología , Biología
8.
Drug Test Anal ; 2024 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-38229238

RESUMEN

As cannabidiol (CBD) is not considered to be a drug and because of its potential health claims, it is an interesting compound that is often found in cosmetics. However, the safety of CBD, as well as the presence of trace amounts of other phytocannabinoids, including the psychoactive substance ∆9 -tetrahydrocannabinol (THC), is still being debated. A robust analytical technique capable of analysing cosmetic products and determining their phytocannabinoid content will be crucial in assessing the safety of these products. This systematic review aims to highlight the current analytical tools that could be used to analyse phytocannabinoids in cosmetics. The ideal method would be able to analyse high levels of CBD in combination with trace levels of THC and their acids. The method should provide good recoveries and accuracies in a variety of matrices while providing information on up-coming phytocannabinoids such as cannabichromene (CBC), cannabigerol (CBG) and cannabinol (CBN). The systematic review approach was based on the Preferred Reporting Items for Systematic review and Meta-Analyses method. The research focused on studies published from January 2010 to December 2022 in PubMed and Scopus. A total of 15 datasets met the inclusion and exclusion criteria and were tabulated to allow easy comparison. Although some of the reviewed methods can handle multiple matrices and provide satisfactory recoveries, this review process did not identify an ideal method. The most suitable methods either could not quantify phytocannabinoid acids or were not sensitive enough to quantify trace levels of psychoactive phytocannabinoids.

9.
Drug Test Anal ; 16(1): 99-104, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37173289

RESUMEN

Whipped cream canisters, also known as nitrous oxide whippets, are traditionally used in the culinary arts to prepare food foams. In recent years, however, these gas canisters have been cracked open and inhaled to produce a "legal" high. Users of these whippets have reported the presence of an oily residue containing metallic particles. This contamination was investigated using liquid chromatography-, gas chromatography- and inductively coupled plasma-mass spectrometry (ICP-MS) and optical emission spectrometry (ICP-OES). The particulate matter was also analyzed by scanning transmission electron microscopy (STEM) combined with energy-dispersive X-ray spectroscopy (EDX). The presence of cyclohexyl isothiocyanate was confirmed at a maximum concentration of 67 µg per whippet. ICP-MS and ICP-OES analysis revealed the presence of mainly iron and zinc, but also, traces of aluminum, chromium, cobalt, nickel, and lead were found. STEM-EDX analysis confirmed the presence of nano-sized particles containing iron and zinc. When simulating inhalation, using the multiple path particle dosimetry model, it was confirmed that these nano-sized particles can reach the deeper parts of the lungs. Most users assume that inhaling a food-grade nitrous oxide whippet for a "legal" high poses no risks. However, this research shows that users are exposed to cyclohexyl isothiocyanate, a substance classified as a respiratory sensitizer. The presence of zinc in the particulate matter could potentially be linked to lung lesions.


Asunto(s)
Drogas Ilícitas , Óxido Nitroso , Cromatografía de Gases y Espectrometría de Masas , Zinc , Hierro , Material Particulado , Isotiocianatos
10.
Drug Test Anal ; 2023 Dec 12.
Artículo en Inglés | MEDLINE | ID: mdl-38086368

RESUMEN

More and more countries and organisations emphasise the value of harm reduction measures in the context of illicit drug use and abuse. One of these measures is drug checking, a preventive action that can represent a quick win by tailored consultation on the risks of substance use upon analytical screening of a submitted sample. Unlike drop-in centres that operate within a fixed setting, enabling drug checking in a harm reduction context at events requires portable, easy to use analytical approaches, operated by personnel with limited knowledge of analytical chemistry. In this case study, four different approaches were compared for the characterisation of 3,4-methylenedioxymethamphetamine samples and this in the way the approaches would be applied today in an event context. The four approaches are mid-infrared (MIR), near-infrared, and Raman spectroscopy, which are today used in drug checking context in Belgium, as well as an electrochemical sensor approach initially developed in the context of law enforcement at ports. The MIR and the electrochemical approach came out best, with the latter allowing for a direct straightforward analysis of the percentage 3,4-methylenedioxymethamphetamine (as base equivalent) in the samples. However, MIR has the advantage that, in a broader drug checking context, it allows to screen for several molecules and so is able to identify unexpected active components or at least the group to which such components belong. The latter is also an important advantage in the context of the growing emergence of new psychotropic substances.

11.
Drug Test Anal ; 2023 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-38043940

RESUMEN

In 2019, a global viral pandemic, due to the SARS-CoV-2 virus, broke out. Soon after, the search for a vaccine and/or antiviral medicine began. One of the candidate antiviral medicines tested was ivermectin. Although several health authorities warned the public against the use of this medicine outside clinical trials, the drug was widely used at the end of 2020 and in 2021. Simultaneously, several reports started to emerge demonstrating serious adverse effects after self-medicating with ivermectin. It stands to reason that the self-administration of substandard or falsified (SF) medicines bearing harmful quality deficiencies have contributed to this phenomenon. In order to have a better view on the nature of these harmful quality deficiencies, SF ivermectin samples, intercepted in large quantities by the Belgian regulatory agencies during the period 2021-2022, were analyzed in our official medicines control laboratory. None of the samples (n = 19) were compliant to the quality criteria applicable to medicinal products. These SF products either suffered from a systematic underdosing of the active pharmaceutical ingredient or were severely contaminated with bacteria, two of which were contaminated with known pathogens that cause gastrointestinal illness upon oral intake. In addition to the direct risks of self-medicating with such a product, the improper usage and dosage of ivermectin medication might also facilitate ivermectin tolerance or resistance in parasites. This may have detrimental consequences on a global scale, certainly as the number of newly developed active pharmaceutical ingredients that can safely be used to combat parasites is rather scarce.

12.
Drug Test Anal ; 2023 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-37793648

RESUMEN

The availability of cannabidiol (CBD) oil products has increased in recent years. No analytical controls are mandatory for these products leading to uncertainties about composition and quality. In this paper, a methodology was developed to identify the oil matrix and to estimate the CBD content in such samples, using mid-infrared and near-infrared spectroscopy. Different oils were selected based on the information labeled on products and were bought in food stores in order to create a sample set with a variety of matrices. These oils were spiked with CBD to obtain samples with CBD levels from 0% to 20%. The first part of the study was focused on the qualitative analysis of the oil matrix. A classification model, based on Soft Independent Modeling of Class Analogy, was build using the spiked oils to distinguish between the different oil matrices. For both spectroscopic techniques, the sensitivity, the specificity, the accuracy and the precision were equal to 100%. These models were applied to determine the oil matrix of seized samples. The second part of the study was focused on the quantitative estimation of CBD. After determination of CBD in seized samples using gas chromatography-tandem mass spectrometry, partial least square regression (PLS-R) models were built, one for each matrix in the sample set. Both techniques were able to classify unknown oily samples according to their matrix, and although only few samples were available to evaluate the PLS-R models, the approach clearly showed promising results for the estimation of the CBD content in oil samples.

13.
Arch Toxicol ; 97(9): 2453-2461, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37414884

RESUMEN

The in chemico direct peptide reactivity assay (DPRA) is validated to assess protein reactivity of chemical compounds, relating to the molecular initiating event of skin sensitization induction. According to OECD TG 442C, the DPRA is technically applicable to test multi-constituent substances and mixtures of known composition, even though limited experimental data are publicly available. First, we assessed the DPRA's predictive capability for individual substances, but at concentrations other than the recommended 100 mM, i.e., based on the LLNA EC3 concentration (Experiment A). Next, the applicability of the DPRA to test unknown mixtures was assessed (Experiment B). Here, the complexity of unknown mixtures was reduced to mixtures containing either two known skin sensitizers with varying potencies, or a combination of a skin sensitizer with a non-skin sensitizer, or multiple non-sensitizers. Experiments A and B revealed that one extremely potent sensitizer (oxazolone) was incorrectly classified as a non-sensitizer when tested at its low EC3 concentration of 0.4 mM instead of the suggested molar excess conditions of 100 mM (Experiments A). For binary mixtures tested in experiments B, the DPRA was able to distinguish all skin sensitizers and the strongest skin sensitizer in the mixture was determinant for the overall peptide depletion of a sensitizer. In conclusion, we confirmed that the DPRA test method can be used efficiently for well-known characterized mixtures. However, when deviating from the recommended testing concentration of 100 mM, caution should be taken in case of negative results, limiting the DPRA's applicability for mixtures of unknown composition.


Asunto(s)
Alternativas a las Pruebas en Animales , Péptidos , Animales , Péptidos/química , Alternativas a las Pruebas en Animales/métodos
14.
Hemasphere ; 7(5): e861, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37125257

RESUMEN

Patients (pts) with asymptomatic low-burden follicular lymphoma (FL) are usually observed at diagnosis. Time to lymphoma treatment (TLT) initiation can however be very heterogeneous and risk factors of progression are poorly studied. Our study evaluated 201 pts with grade 1-3a low-tumor burden FL diagnosed in four French centers between 2010 and 2020 and managed by a watch and wait strategy in real-life settings. After a median follow-up of 4.8 years, the median TLT was 4.2 years (95% confidence interval, 3.1-5.5). On multivariate analysis, elevated lactate dehydrogenase (hazard ratio [HR] = 2.2; P = 0.02), more than 4 nodal areas involved (HR = 1.7; P = 0.02) and more than 1 extranodal involvement (HR = 2.7; P = 0.01) were identified as independent predictors of TLT. The median TLT was 5.8 years for pts with no risk factor, 2.4 years for 1 risk factor, and 1.3 years for >1 risk factors (P < 0.01). In a subanalysis of 75 pts staged with positron emission tomography-computed tomography (PET-CT), total metabolic tumor volume (TMTV) ≥14 cm3 and standardized Dmax (reflecting tumor dissemination) >0.32 m-1 were also associated with shorter TLT (HR = 3.4; P = 0.004 and HR = 2.4; P = 0.007, respectively). In multivariate models combining PET-CT parameters and clinical variables, TMTV remained independent predictor of shorter TLT. These simple parameters could help to identify FL patients initially observed at higher risk of early progression. The role of PET-CT (extranodal sites and PET metrics) in low-burden FL appears promising and warrants further assessment in large cohorts.

15.
Eur J Haematol ; 111(2): 181-190, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37082839

RESUMEN

BACKGROUND: No adequate data exist on the impact of multiple myeloma (MM) with extramedullary disease (EMD) after autograft and maintenance therapy. METHODS: We identified 808 patients with newly diagnosed MM who received first autograft, of whom 107 had EMD (83 paraskeletal and 24 organ involvement), and who had been reported to the EBMT registry December 2018. Distribution according to type of involvement was similar between the treatment groups (p = .69). For EMD, 46 (40%) received thalidomide, 59 (51%) lenalidomide, and 11 (10%) bortezomib. RESULTS: The median follow-up from maintenance start was 44 months. Three-year progression-free survival (PFS) was 52% (48%-57%) for no EMD, 56% (44%-69%) for paraskeletal involvement, and 45% (22%-68%) for organ involvement (p = .146). Early PFS (within first year) appeared to be significantly worse for organ involvement (hazard ratio, 3.40), while no significant influence was found after first year from maintenance start. Three-year overall survival (OS) was 81% (77%-84%), 88% (80%-96%), and 68% (47%-89%; p = .064), respectively. With thalidomide as reference, lenalidomide was significantly associated with better PFS and OS, whereas bortezomib appeared to improve outcome specifically in EMD. CONCLUSION: Lenalidomide maintenance is standard of care for MM without EMD, whereas extramedullary organ involvement remains a significant risk factor for worse outcome, especially for early events after maintenance start.


Asunto(s)
Mieloma Múltiple , Humanos , Mieloma Múltiple/terapia , Mieloma Múltiple/tratamiento farmacológico , Bortezomib/uso terapéutico , Lenalidomida/uso terapéutico , Talidomida/uso terapéutico , Autoinjertos , Trasplante Autólogo , Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Dexametasona/uso terapéutico
16.
J Pharm Biomed Anal ; 230: 115394, 2023 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-37062207

RESUMEN

The use of cannabidiol or CBD products has skyrocketed in the last five years due to the alleged therapeutic benefits, a low potential for abuse and lack of the typical psychoactive effects associated with the use of cannabis products containing high levels of ∆9-tetrahydrocannabinol (∆9-THC). In Belgium, CBD-containing e-liquids with a total THC content lower than 0.2% (w/w) are currently legal. In order to verify the compliance of the different CBD-containing e-cigarette liquids that are available to the Belgian population, a method was developed for screening of 17 cannabinoids and to quantify the major cannabinoids such as CBD, CBDA, ∆9-THC and ∆9-THCA. The latter was fully validated using the 'total error' approach, applying accuracy profiles and conforming to ISO17025. None of the analysed samples exceeded the legal limit for the total amount of ∆9-THC present. However, of the 20 CBD-liquids investigated in this study, only 30% of the samples contained an amount of CBD that was within 10% deviation of the label claim. Moreover, the CBD e-liquids labelled "full/broad spectrum" consisted of several minor alkaloids in comparison to the "classic" CBD e-liquids where the acidic forms of the cannabinoids were not present. Currently, no legislation is available for the regulation of CBD e-liquids, however these results indicate that quality controls are pertinent especially concerning the discrepancy in CBD label accuracy.


Asunto(s)
Cannabidiol , Cannabinoides , Cannabis , Sistemas Electrónicos de Liberación de Nicotina , Cannabinoides/análisis , Cannabidiol/análisis , Cromatografía Liquida , Espectrometría de Masas , Dronabinol/análisis
17.
Molecules ; 28(8)2023 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-37110870

RESUMEN

The popularity of plant food supplements has seen explosive growth all over the world, making them susceptible to adulteration and fraud. This necessitates a screening approach for the detection of regulated plants in plant food supplements, which are usually composed of complex plant mixtures, thus making the approach not so straightforward. This paper aims to tackle this problem by developing a multidimensional chromatographic fingerprinting method aided by chemometrics. To render more specificity to the chromatogram, a multidimensional fingerprint (absorbance × wavelength × retention time) was considered. This was achieved by selecting several wavelengths through a correlation analysis. The data were recorded using ultra-high-performance liquid chromatography (UHPLC) coupled with diode array detection (DAD). Chemometric modelling was performed by partial least squares-discriminant analysis (PLS-DA) through (a) binary modelling and (b) multiclass modelling. The correct classification rates (ccr%) by cross-validation, modelling, and external test set validation were satisfactory for both approaches, but upon further comparison, binary models were preferred. As a proof of concept, the models were applied to twelve samples for the detection of four regulated plants. Overall, it was revealed that the combination of multidimensional fingerprinting data with chemometrics was feasible for the identification of regulated plants in complex botanical matrices.


Asunto(s)
Quimiometría , Plantas , Suplementos Dietéticos/análisis , Análisis Discriminante , Análisis de los Mínimos Cuadrados , Cromatografía Líquida de Alta Presión/métodos
18.
Artículo en Inglés | MEDLINE | ID: mdl-36901637

RESUMEN

BACKGROUND: Drug checking is a proven harm reduction strategy and provides real-time information on the market of new psychoactive substances (NPS). It combines chemical analysis of samples with direct engagement with people who use drugs (PWUD), giving the ability to increase preparedness and responsiveness towards NPS. Next to that, it supports rapid identification of potential unwitting consumption. However, NPS cause a toxicological battle for the researchers, as factors such as the unpredictability and quick shift of the market complicate the detection. METHODS: To evaluate challenges posed towards drug checking services, proficiency testing was set up to evaluate existing analytical techniques and investigate the capability to correctly identify circulating NPS. Twenty blind substances, covering the most common categories of substances, were analyzed according to the existing protocols of the existing drug checking services, including several analytical methods such as gas chromatography-mass spectrometry (GC-MS) and liquid chromatography with diode array detector (LC-DAD). RESULTS: The proficiency test scores range from 80 to 97.5% accuracy. The most common issues and errors are mainly unidentified compounds, presumably due to no up-to-date libraries, and/ or confusion between structural isomers, such as 3- and 4-chloroethcathinone, or structural analogs, such as MIPLA (N-methyl-N-isopropyl lysergamide) and LSD (D-lysergic acid diethylamide). CONCLUSIONS: The participating drug checking services have access to adequate analytical tools to provide feedback to drug users and provide up-to-date information on NPS.


Asunto(s)
Reducción del Daño , Psicotrópicos , Humanos , Cromatografía de Gases y Espectrometría de Masas/métodos , Cromatografía Liquida/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...